  FC2187 non contractual documentation C firelec can improve the design or the specifications of the product describ ed herein without prior notification page 1/3 bulletin rev: 12_2009 FC2187 2 channels C converter module 1-5vdc to 4-20ma description: the module FC2187 is used as interface between the instruments located in the field area and the control room . the module FC2187 has two 1-5vdc input channels. each input is isolated from the other one and from its output. for each channel the input signal 1-5vdc is convert ed with accuracy after isolation into 4-20ma. product options: option st :FC2187-st: signal connected using screw terminals option cct :FC2187-cct: signal connected using cage clamp or spring terminals main characteristics: 2 input channels 1C5vdc converted into 4- 20ma galvanic isolation between each input and between input and output din rail mounting, on termination panel modulo 8 or individual socket
FC2187 non contractual documentation C firelec can improve the design or the specifications of the product describ ed herein without prior notification page 2/3 bulletin rev: 12_2009 technical specifications power supply voltage range: 20vdc to 28vdc power on indication: by green led on front plate consumption (25vdc): 125 ma with all channels at 100% replaceable fuse: 200 ma 250v quick action input specifications for each channel protection: against over voltage input range: 1C5vdc input impedance: 100k ? output specifications for each channel current: 4-20ma high limit: 30ma +/- 1ma max load: 500 ohms at 20ma output transfer characteristics for each channel accuracy at 20c ambient: better than 0,15% response time: 90% of the final value within 50ms. drift: 0,01%/c isolation voltage ( input 1 / input 2 / output ): 1500vdc common mode rejection at 220v: dc: without measurable effect ac (50hz): 120 db mechanical and environment characteristics protection: ip20 wiring conductor section: option st: 24 to 12 awg (0.2 to 2.5 mm2) option cct: 24 to 12 awg (0.2 to 2.5 mm2) weight: 100g size: h=85mm w=16mm d=120mm with front connector operating temperature: -10c to 50c storage temperature: -20c to 60c relative humidity: 10 to 90% (no condensation) mounting: panel modulo 8 type fc8308-1 or fc8308-2 ( see documentation fc8308 ) or individual socket type fcsoc-2ai
FC2187 non contractual documentation C firelec can improve the design or the specifications of the product describ ed herein without prior notification page 3/3 bulletin rev: 12_2009 socket for individual mounting on din rail FC2187 installed on fcsoc-2ai socket individual socket characteristics reference of individual socket: fcsoc-2ai power supply connection: screw terminal b (+) and a (-) awg 14 to 26 or 0.14 to 1.5mm2 fuse protection on power supply: 1a protection: against over voltage and reverse polarity output channel 1 connection: screw terminals g (+) and f (-) awg 14 to 26 or 0.14 to 1.5mm2 output channel 2 connection: screw terminals e (+) and d (-) awg 14 to 26 or 0.14 to 1.5mm2


▲Up To Search▲   

 
Price & Availability of FC2187

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X